[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: ichwd for ICH8



At 08:13 PM 7/26/2007, Dag-Erling Smørgrav wrote:
Mike Tancsa <mike_(_at_)_sentex_(_dot_)_net> writes:
> OK, I tried it on current, but it sees the ichwd as ich5, where as its
> 7 according to the other version

No, the unpatched driver in -CURRENT has that bug (misidentifies ICH7 as
ICH5) but the patched driver would identify it correctly and
additionally print a line about the TCO version.  You must have loaded
the wrong module.

Sorry, you are right. I can load it now on the current box I have running, but it doesnt reboot it, probably because of the BIOS setting.

ichwd module loaded
ichwd0: <Intel ICH7 watchdog timer> at port 0x1080-0x1087,0x1088-0x1091 on isa0
ichwd0: Intel ICH7 watchdog timer (ICH7 or equivalent)
ppc0: parallel port not found.



Also, it works on RELENG_6

ichwd module loaded
ichwd0: <Intel ICH7 watchdog timer> on isa0
ichwd0: Intel ICH7 watchdog timer (ICH7 or equivalent)
ppc0: parallel port not found.


I also tried the patched version on an older box and it looks good too (running releng_6). Its an ICH5 Intel 865 MB

ichwd module loaded
ichwd0: <Intel 82801EB/ER watchdog timer> on isa0
ppc0: parallel port not found.